Downdraft Ventilators
Page 1
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Do not install this product with the activating switch directly behind
a burner or element. Minimum distance between the switch and the
edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn when operating
this appliance. They may be ignited by burners/elements on cooktop.
10. Children should not be left alone or unattended in the area where this
appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF
A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING
a
:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
- a violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a
Based on “Kitchen Firesafety Tips” published by NFPA.
MODEL WIDTH BLOWER
RMDD3004 30" 500 cfm Internal
RMDD3604 36" 500 cfm Internal
RMDD4804 48" 500 cfm Internal
RMDD3004EX 30" Models 331H, 332H, 335, 336 HLB3, HLB6, HLB9, and HLB11 External (purchase separately)
RMDD3604EX 36" Models 331H, 332H, 335, 336 HLB3, HLB6, HLB9, and HLB11 External (purchase separately)
RMDD4804EX 48" Models 331H, 332H, 335, 336 HLB3, HLB6, HLB9, and HLB11 External (purchase separately)
WARNING - To reduce the risk of burns or ignition of clothing by reaching across burners, the downdraft remote control MUST
be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8.
!
INSTALLER:
Save this manual for Electrical
Inspector and Homeowner to use.
NOTE: Model RMDDRBK Remote Up/Down
Control sold separately.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless specifically
recommended in this manual. All other servicing should be done by
a qualified technician.
6. Please read specification label on product for further information and
requirements.
7. To reduce the risk of fire and electric shock, install this downdraft only
with Rangemaster blower models shown below. Other blowers cannot
be substituted. (blowers sold separately).
MODEL WIDTH BLOWER
RMDD3004 30" 500 cfm Internal
RMDD3604 36" 500 cfm Internal
RMDD4804 48" 500 cfm Internal
RMDD3004EX 30" External, Model 331H, 332H, 335, 336,
HLB3, HLB6, HLB9, y HLB11 (purchase
separately)
RMDD3604EX 36" External, Model 331H, 332H, 335, 336,
HLB3, HLB6, HLB9, y HLB11 (purchase
separately)
RMDD4804EX 48" External, Model 331H, 332H, 335, 336,
HLB3, HLB6, HLB9, y HLB11 (purchase
separately)
Register your product online at: www.broan.com/register
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - INSTALLER:

Downdraft VentilatorsPage 1WARNINGREAD AND SAVE THESE INSTRUCTIONSWARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE

Strany 2 - TAKE MEASUREMENTS

Page 10Downdraft VentilatorsBACKSIDE OFREMOTE SWITCH TEMPLATEUSE AND CAREAlways turn the downdraft blower on before you begin cooking to establish an

Strany 3 - TAKE MEASUREMENTS (CONTINUED)

Downdraft VentilatorsPage 11OPERATIONNote: For most convenient operation, set the blower to your favo-rite speed. The blower will come on to this spee

Strany 4 - Blower Installation

Page 12Downdraft VentilatorsSERVICE PARTSWARRANTYBROAN ONE YEAR LIMITED WARRANTYBroan warrants to the original consumer purchaser of its products that

Strany 5 - PREPARE THE DOWNDRAFT

Downdraft VentilatorsPage 13SERVICE PARTS

Strany 6 - CUT COUNTERTOP OPENING

Page 14Downdraft VentilatorsADVERTENCIALEA Y CONSERVE ESTAS INSTRUCCIONESADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉC-TRICAS O LESIO

Strany 7 - INSTALL DUCTWORK

Downdraft VentilatorsPage 15INSTALACIÓN TÍPICAEl sistema de ventilación de tiro descendente está diseñado para descargar los contaminantes transportad

Strany 8 - INSTALL COOKTOP

Page 16Downdraft Ventilators29 "5162 "18VIDV500INTERNALBLOWER5"2"1"3 "143 "58147 "1116SIDE VIEWVIPR

Strany 9

Downdraft VentilatorsPage 17CENTER LINEOF COUNTERCUTOUTCENTERLINES OFDUCT CUTOUT221/8"(19" FOREXTERNALBLOWER)10¼" x 3½"CUTOUT(14¼&

Strany 10 - All Units

Page 18Downdraft VentilatorsPLANEE EL CABLEADO ELÉCTRICO1. El sistema de ventilación de tiro descendente exterior o en línea requiere 6 AMPERIOS y un

Strany 11 - WIRING DIAGRAM

Downdraft VentilatorsPage 19HAGA LA ABERTURA DE LA SUPERFICIE DEL GABINETETodas las unidades1. Trace y haga el corte para la estufa lo suficientement

Strany 12 - SERVICE PARTSWARRANTY

Page 2Downdraft VentilatorsAIRVENTCOUNTERTOPBLOWERBOXCHIMNEY TOPCOOK TOPGEARMOTORCOVERTYPICAL INSTALLATION120 VAC GROUNDED OUTLETThis downdraft blower

Strany 13 - SERVICE PARTS

Page 20Downdraft Ventilators1. Haga el orificio en el gabinete así como los orificios en la pared o el piso según sea necesario.2. Monte la tapa de

Strany 14 - PRECAUCIÓN

Downdraft VentilatorsPage 21INSTALE EL CABLEADO ELÉCTRICO1. Monte una caja de cableado estándar, con un receptáculo para tres patas, dentro del gabin

Strany 15 - TOME MEDIDAS

Page 22Downdraft VentilatorsINSTALACIÓN DEL CONTROL REMOTO DE ASCENSO/DESCENSO (OPCIONAL)Instalación1. Usando la plantilla que aparece a la derecha,

Strany 16 - TOME MEDIDAS (CONTINUACIÓN)

Downdraft VentilatorsPage 23PARTE POSTERIOR DE LA PLANTILLA DEL CONMUTADOR REMOTOUSO Y CUIDADOSiempre encienda el ventilador del tiro descendente ante

Strany 17

Page 24Downdraft VentilatorsOPERACIÓNVentiladores de tiro descendentePágina 24Dé vuelta al soplador apagado presionando el interruptor que activa otra

Strany 18

Downdraft VentilatorsPage 25PIEZAS DE SERVICOGARANTIA 76,2 cm 91,4 cm 122 cmCLAVE (30") (36") (48") NO. DE ANCHO DE ANCHO DE

Strany 19 - Todas las unidades

Page 26Downdraft VentilatorsPIEZAS DE SERVICIOVentiladores de tiro descendentePágina 26

Strany 20 - Instalación del ventilador

Downdraft VentilatorsPage 27!AVERTISSEMENTLIRE ET CONSERVER CES INSTRUCTIONSAFIN DE DIMINUER LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES,

Strany 21

Page 28Downdraft VentilatorsCOMPTOIRBOÎTIER DU VENTILATEURBOUCHE DE CHEMINÉERACCORD DE CONDUIT 8,3 cm X 25,4 cm (3-1/4 po X 10")SURFACE DE CUISSO

Strany 22

Downdraft VentilatorsPage 29SORTIE GAUCHESORTIE INFÉ-RIEURESORTIE DROITEPRÉPARATION DES CONDUITSInstallation du ventilateur intérieurPRISE DES MESURES

Strany 23

Downdraft VentilatorsPage 31. The interior down-draft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to

Strany 24 - DIAGRAMA DEL CABLEADO

Page 30Downdraft VentilatorsCENTER LINEOF COUNTERCUTOUTCENTER LINEOF DUCTCUTOUT¼" to 7¾"5½"(4¼" FOREXTERNALBLOWER)10¼" x 3½&q

Strany 25 - PIEZAS DE SERVICOGARANTIA

Downdraft VentilatorsPage 31PRÉPARATION DU CÂBLAGEInstallation du ventilateur intérieur1. Le ventilateur encastré extérieur consomme 6 AMPÈRES et néc

Strany 26 - PIEZAS DE SERVICIO

Page 32Downdraft Ventilators1. Tracer et découper la forme de la table de cuisson dans le comptoir, suffisamment vers l’AVANT afin de pouvoir insérer

Strany 27 - ATTENTION

Downdraft VentilatorsPage 331. Découpez les trous dans l’armoire, le mur ou le plancher.2. Installez le chapeau de toit ou de mur et travaillez en p

Strany 28 - Tous les appareils

Page 34Downdraft VentilatorsCÂBLAGE ÉLECTRIQUEInstallation du ventilateur intérieur1. Installez une boîte électrique standard avec une prise à trois

Strany 29

Downdraft VentilatorsPage 35INSTALLATION DE LA TÉLÉCOMMANDE HAUT/BAS (FACULTATIF)Installation1. À l’aide du gabarit de droite, disposez les 3 trous s

Strany 30

Page 36Downdraft VentilatorsUTILISATION ET ENTRETIENActionnez toujours la hotte encastrée avant de commencer à cuisiner afin de créer un courant d’air

Strany 31 - PRÉPARATION DE LA HOTTE

Downdraft VentilatorsPage 37UTILISATIONNote: Pour la plupart d'opération commode, placez le ventilateur à votre vitesse préférée. Le ventilateur

Strany 32 - DÉCOUPAGE DU COMPTOIR

Page 38Downdraft VentilatorsPIÈCES DE RECHANGEGARANTIE 76,2 cm 91,4 cm 122 cm (30") (36") (48") Légende Largeur Largeur

Strany 33 - Installation du ventilateur

Downdraft VentilatorsPage 39Ventilateurs séries de créateurencastrés de conceptionPIÈCES DE RECHANGE

Strany 34

Page 4Downdraft VentilatorsCENTER LINEOF COUNTERCUTOUTCENTER LINEOF DUCTCUTOUT¼" to 7¾"5½"(4¼" FOREXTERNALBLOWER)10¼" x 3½&qu

Strany 35

99043101K

Strany 36 - DE LA TÉLÉCOMMANDE

Downdraft VentilatorsPage 5PLAN THE WIRINGInternal Blower Installation External Blower Installation1. The External Downdraft Blower system draws 6 AM

Strany 37 - DIAGRAMME DE CÂBLAGE

Page 6Downdraft VentilatorsCUT COUNTERTOP OPENINGAll Units1. Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it.2

Strany 38 - PIÈCES DE RECHANGEGARANTIE

Downdraft VentilatorsPage 71. Cut hole in cabinet as well as holes in wall or floor as neces-sary.2. Mount the roof or wall cap and work back toward

Strany 39 - PIÈCES DE RECHANGE

Page 8Downdraft VentilatorsINSTALL ELECTRICAL WIRINGInternal Blower Installation1. Mount a standard wiring box, with 3-pronged receptacle, inside the

Strany 40 - 99043101K

Downdraft VentilatorsPage 9REMOTE UP/DOWN CONTROL INSTALLATION (OPTIONAL)Installation1. Using the template at right, lay out the 3-hole pattern on th